STEICOprotect dry

Type H Type M Type L
Board designation WF-EN13171-T5-DS(70,90)3-CS(10\Y)200-TR30-BS500-WS1,0-MU3 WF-EN13171-T5-DS(70,90)3-CS(10\Y)100-TR20-BS500-WS1,0-MU3 WF-EN13171-T5-DS(70,90)3-CS(10\Y)50-TR10-WS1,0-MU3
Fire class according to EN 13501-1 E E E
Declared thermal conductivity λD [W/(m*K)] 0,043 0,040 0,037
Declared thermal resistance RD [( m² * K )/W] 0,93(40) / 1,40 (60) 1,5(60) / 2(80) / 2,5(100) / 3(120) / 3,5(140) / 4(160) 2,70(100) / 3,20(120) / 3,75(140) / 4,30(160) / 4,85(180) / 5,40(200) / 5,90(220) / 6,45(240)
Board Density [kg/m³] ca. 180 ca. 140 ca. 110
Water vapour diffusion resistance factor μ 3 3 3
Specific heat capacity [J/(kg*K)] 2100 2100 2100
Compression strength [kPa] 200 100 50
Tensile strength perpendicular to face [kPa] 30 20 10
Dimensional stability 48 h, 70 °C, 90 % relative air moisture Länge Δεl ≤ 3%, Breite Δεb ≤ 3%, Dicke Δεd ≤ 3% Länge Δεl ≤ 3%, Breite Δεb ≤ 3%, Dicke Δεd ≤ 3% Länge Δεl ≤ 3%, Breite Δεb ≤ 3%, Dicke Δεd ≤ 3%
Waste code (EAK) 030105 / 170201 030105 / 170201 030105 / 170201